DPF warning and engine management light on Audi A4 2.0 TDI. Filter blocked and cannot complete regeneration cycle. This fault code is stored when the engine control unit detects a specific fault condition. Common causes include sensor failures, wiring faults, and component wear. Always read additional fault codes before replacing parts — multiple codes together provide a clearer diagnosis. Clear the code after repair and test drive to confirm the fault does not return.
⚙️ Possible Causes
Possible: EGR valve was blocking regeneration — cleaned bothPossible: Forced regen via VCDS — sorted in 45 minutes
Repair / Solution
Based on 0 driver confirmations
EGR valve was blocking regeneration — cleaned both0%
0 worked · 0 did not· GBP 250 – 400· ⚪ Unverified🔧 Mechanic verified
Forced regen via VCDS — sorted in 45 minutes0%
0 worked · 0 did not· GBP 50 – 80· ⚪ Unverified🔧 Mechanic verified
⚠️ Wrong Diagnosis?
No commonly reported misdiagnoses for this fault yet.
If you have replaced a part that did not fix this Audi problem,
submit a wrong diagnosis report
— it helps other drivers avoid the same costly mistake.
🧾 Driver Reports
✅ FixedEGR valve was blocking regeneration — cleaned both
DPF kept blocking every few months. Regen kept failing. Root cause was the EGR valve was so carbon-fouled it was reducing exhaust temperatures needed for regen. Cleaned both EGR and DPF at the same time. Been 8 months, no DPF issues since.
Parts replaced: EGR cleaner, DPF cleaning service
💰 GBP 250 – 400🔧 Mechanic verified
Was this helpful?0 votes
✅ FixedForced regen via VCDS — sorted in 45 minutes
DPF warning, auto regen wasn't completing. Took it to a specialist with VCDS who did a forced regeneration on the ramp. 45 minutes at elevated idle, DPF cleared completely. £60 for the session. Much cheaper than a new filter.